Power Consumption Measurement

Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.

Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver: 2.0

Device Under Test
DUT: Sys #1

Test Procedure
1. Power up the DUT and then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.

APPC 1720T/1721T

+12V

+24V

+30V

Full-Loading Mode

3.31A

1.66A

1.36A

Total

39.72W

39.84W

40.8W

Standby Mode

1.06A

0.57A

0.47A

Total

12.72W

13.68W

14.1W

APPC 1520T/1521T

+12V

+24V

+30V

Full-Loading Mode

2.7A

1.4A

1.13A

Total

32.4W

33.6W

33.9W

Standby Mode

1.04A

0.54A

0.44A

Total

12.48W

12.96W

13.2W

APPC 1220T/1221T

+12V

+24V

+30V

Full-Loading Mode

1.84A

0.93A

0.75A

Total

22.08W

22.32W

22.5W

Standby Mode

0.93A

0.49A

0.4A

Total

11.16W

11.76W

12W