KBC Networks FPCD1-M4T-R-M1A User Manual
Page 9

Manual-FPCB1-Rev1012.pdf
Page 9 of 11
Copyright © KBC Networks Ltd.
Receiver Left View
Connectors:
+
:
+
12VDC
-
: Power Supply Ground
RX1: Channel 1 Fiber Optic
RX2: Channel 2 Fiber Optic
RX3: Channel 3 Fiber Optic
RX4: Channel 4 Fiber Optic
LEDs Definition:
POW:
Power Supply. On if power input is in OK.
SYNC: Channel 4 Fiber link. Off if the fiber link is in OK.
2.4 Operate Instruction
1) Connect transmitter to monitor via DVI cable.
2) Turn on monitor and transmitter.
3) Press the button at transmitter until the STS LED stops flashing (accompanying a
beep), this indicates that the transmitter is reading EDID data from monitor .Then
release the button.
4) In about 30 seconds, the STS LED flashes again accompanying a beep, this
indicates the successful reading of EDID. If the STS LED flashes without beep, this
indicates the failure of reading EDID. Try to operate again and check DVI cable if
necessary.
5) After reading EDID data, connect transmitter DVI port to PC host DVI port.
2.5 Caution
•
Switch off all power supply before installation
•
Ensure fiber is properly aligned to the receiving connector
•
Do NOT stare at the fiber core