Ac power, Power consumption, Ac plug – ILUMINARC Ilumipanel™ 180 IP User Manual
Page 11: Power wiring, Operation
Operation
Ilumipanel 180 IP Optic 15/30 RGBWA User Manual Rev. 12
7
Always connect
the Ilumipanel
180 IP Optic
15/30 RGBWA to a
protected circuit with an
appropriate electrical
ground to avoid the risk of
electrocution or fire.
Never connect
the Ilumipanel
180 IP Optic
15/30 RGBWA to a
rheostat (variable resistor)
or dimmer circuit, even if
the rheostat or dimmer
channel serves only as a
0 to 100% switch.
Make sure to
connect the
Ilumipanel 180 IP
Optic 15/30 RGBWA
product to a power line
with the proper voltage
and frequency, as per the
specifications in this
manual or on the
product’s sticker.
The listed
current rating
indicates the
maximum current draw
during normal operation.
If you choose to
bury the power or
signal distribution
boxes, make sure that
they are IP67 rated or
greater.
AC Power
The Ilumipanel 180 IP Optic 15/30 RGBWA has an auto-ranging power supply that works with
an input voltage range of 100~240 VAC, 50/60 Hz.
Make sure you are connecting this product to the proper voltage, as per the specifications in this
manual or on the product’s sticker.
Power Consumption
To determine the power requirements for the Ilumipanel 180 IP Optic 15/30 RGBWA,
refer to the label affixed to the side of the product or refer to the
chart in this manual.
The listed current rating indicates the maximum current draw during normal operation.
AC Plug
The Ilumipanel 180 IP Optic 15/30 RGBWA comes with an un-terminated power
input cord for hardwiring during installation. Use the table and the illustration below
to wire a plug.
Connection
Wire (US)
Screw Color (US)
Wire (Europe) IP67 Pin
AC Live
Black
Yellow or Brass
Brown
1
AC Neutral
White
Silver or Gray
Blue
2
AC Ground
Green/Yellow
Green
Green/Yellow
3
Power Wiring
You can connect the bare-ended IP67 rated AC power cable from the product to an
IP67 rated power connector or IP67 rated junction box.
If using junction boxes, make sure to use IP67 rated conduit for surface installations.