CIRCUTOR EDS Series User Manual
Page 5
EDS
M98237501-03-13A
5.-
Technical specifications
Power circuit:
-
Single-phase (phase – neutral) A1 – A2 :
-
Frequency:
-
Maximum consumption:
-
Working temperature:
-
Water content (non-condensing):
Standard version
85…264 V
ac
/ 120…300 V
dc
47…63 Hz
5…8 VA
-10 …+ 60 ºC
5 … 95 %
Output Features:
-
Type:
-
Maximum switching power:
-
Maximum switching voltage:
-
Maximum switching intensity:
-
Electrical life (250 Vac / 5 A):
-
Mechanical working life:
Relay
750 VA
250 V
ac
5 A with resistive load
3 x 104 operations
2 x 107 operations
Mechanical features:
-
Case material:
-
Equipment protection degree:
-
Dimensions (mm):
-
Weight:
-
Maximum operating height:
UL94 - V0 self-extinguishing plastic
IP 20
105 x 70 x 90 mm (6 modules)
250 g
2,000 m
LED symbols:
-
Power :
-
Slaves:
-
Left RJ45 led:
-
Right RJ45 led:
Equipment power supply and CPU activity
Communicating slave devices shutdown
Green: Full duplex / Yellow: Half duplex / Activity
Green: 100 Mb/s / Yellow: 10 Mb/s / Link
Inputs features:
-
Type:
-
Maximum activation current:
-
Insulation:
Voltage-free opto-insulated (dry contact)
50 mA
1500 V
Display:
-
Type:
-
Characters:
-
Back lighting:
2 lines, alphanumeric
20
Yes
Network interface:
-
Type:
-
Connector:
-
Network protocols:
Ethernet 10BaseT / 100BaseTX self-detectable
RJ45
HTTP / Modbus/RTU in RS-485 bus
Safety:
Installation category Class III / EN61010 double-insulated electric shock protection class II.
Connect the device to a power circuit protected with gl fuses in compliance with IEC 269, or
M fuses, with values from 0.5 to 1A. It must be fitted with a circuit breaker switch or
equivalent device, in order to be able to disconnect the device from the power supply. The
power supply cable must have a cross-section of at least 1 mm
2
.
Standards:
EC, UL 94, EN61010-1, EN55011, EN 61000-4-2, EN 61000-4-3,
61000-4-11, EN 61000-6-4, EN 61000-6-2, EN 61000-6-1, EN 61000-6-3, EN 61000-4-5
Serial interface:
-
Type:
-
Transmission speed (configurable):
-
Data bits:
-
Parity:
-
Stop bit
Three-wire RS-485 (A/B/S)
4800, 9600, 19,200, 34,800, 57,600, 115,200 bps
8
No parity, odd, even
1 / 2
6.-
Connections
DETAILS OF THE POWER SUPPLY AND RS-485 COMMUNICATION (SLAVE EQUIPMENT)
CONNECTIONS
DETAILS OF DIGITAL INPUT 4 ACTIVATION
7.-
Technical Service
If you have any doubts about the operation of the unit or suspect any malfunction, contact our service staff at CIRCUTOR, SA
CIRCUTOR, SA - Technical Assistance Service
Vial Sant Jordi, s/n
08232 – Viladecavalls (Barcelona), SPAIN
Tel.: 902 449 459 (Spain)
Tel.: +34 937 452 900 (outside Spain)
e-mail: