Casella CEL Airborne particulate monitoring system User Manual
Page 16

HB3256-03
Page 14
System wiring.
The basic system wiring is simple providing the manual is studied carefully and care is taken.
Wiring should only be carried out by qualified personnel who are familiar with the procedures
and precautions necessary when wiring such electronic devices.
Warning:
INCORRECT WIRING MAY RESULT IN DAMAGE TO THE SYSTEMS OR
SENSORS. SUCH DAMAGE WILL BE THE CUSTOMERS RESPONSIBILITY AND
IS EXCLUDED FROM THE CONDITIONS OF WARRANTY.
Wind Speed and Direction Sensor Wiring.
The sensors are generally fitted to a cross arm assembly and interconnected to the APM950
system via a small junction box.
Wiring between wind sensors, junction box and APM system is detailed below.
Sensor
connection
Wire colour from
sensor to junction
box
Wire colour
from junction
box to APM
system
APM system
connection
Supply +ve
RED
RED
12 volt supply
(on terminal strip)
Supply 0v
BLACK/WHITE
BLUE
0 volt reference
(on terminal strip)
Windspeed
Signal
GREEN
GREEN
COUNTER 1 input
Wind direction
Signal
GREEN
YELLOW
CH2 + input
Screens
Yellow/Green
Yellow/Green
Chassis earth points