Wind Direction
Description
This sensitive wind vane has been designed and tested to meet the recommendations adopted by
the European Commission CIMO (WMO N272 Brussels 11 - 22 September 1989).
The instrument is constructed using aluminium alloy, which is then anodised. This results in a
durable all weather construction.
Specification
Transducer
Continuous rotation wirewound
potentiometer
Maximum design wind speed
75 metres/second
Aligning threshhold
1.2 metres/second @ 10° offset
Distance constant
Typically 2.3
Undamped natural wavelength
6.2 metres
Damping ratio
0.35 to 0.45
Repeatability
0.5% f.s.d.
Time constant
0.35 second
Electrical angle
0 - 355° (north between 355° and 0°)
Operating temperature range
-20°C to +70°C
Storage temperature range
-50°C to +70°C
Supply voltage
7 to 20 volts d.c.
Current consumption
Typically 2 to 3mA at 12 volts
Output calibration
0 to 1.8 volts d.c. for 0 - 355° rotation.
Deadband = 0 volts output
Part no.
120804B-04