beautypg.com

Eriodic, Aintenance – Dansons Group HCF300 User Manual

Page 28

background image

Copyright 2004

28

Cheap Charlie

Owner’s Manual

Canadian Comfort Industries

www.dansons.com

Dansons Group Inc.

P

ERIODIC

M

AINTENANCE

CONTINUED


INSPECT AND CLEAN THE CHIMNEY:

[ELECTRICAL CORD UNPLUGGED] Under some

conditions fly ash build up in the chimney system may occur rapidly. The fly ash will collect in the exhaust
venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during
startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will
collect in the exhaust venting system. Check the clean out tees and elbows in the exhaust system
periodically to determine the cleaning schedule. To remove dust from the vent pipe, tap lightly on the pipe to
dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of
the vent pipe as possible. 3 or 4-inch chimney brushes are available for chimney cleaning. If the exhaust
system has a screen on it, frequently clean the screen. A plugged screen will shut off combustion air and
cause a fire to die or burn poorly.

PAINTED SURFACES:

Painted surfaces may be wiped down with a damp cloth. If scratches appear or

you wish to renew your paint, contact your Dealer to obtain a can of Satin Black (“Stove Bright”) paint.

Tip: use a hair dryer to warm the surface prior to touching up the paint,

this helps to reduce paint runs.

Note: Do not use any other brand than “Stove Bright” as they may not be compatible.

NOTE: Your

Cheap Charlie

Dealer may offer a periodic stove cleaning service. Check with them on

timing and cost of this service.

FALL START UP:

Prior to lighting the first fire check the outside area around the exhaust and air intake

systems for obstructions. Clean the screens on the exhaust system and the outside air intake pipe. Turn all
controls on to make sure they are working prior to lighting the first fire. Clean and remove fly ash from
exhaust venting. Our local Authorized Dealer should have 3” and 4” chimney brushes available. This is also
a good time to give the entire stove a good cleaning throughout.

SPRING SHUTDOWN:

[COLD STOVE

AND COLD ASHES ONLY]. After the last
burn in the spring remove pellets from the
hopper and the auger. Scoop out the pellets
then run the auger until the hopper is empty
and pellets stop flowing. Vacuum out the
hopper. Thoroughly clean the burn grate,
burn box, ashtray and ash traps. It’s
desirable to spray the inside of the cleaned
hopper with an aerosol silicone spray if your
stove is in a high humidity area. The
exhaust system should be thoroughly
cleaned.

YEARLY SERVICING:

A yearly

servicing and cleaning by your Authorized

Cheap Charlie

Dealer is recommended. A

fee may be charged for this service.

Figure 30

Window

Burn Pot

Burn Grate

Heat Tubes

Tube Scraper

Ash Pit

Hopper

Fan Motors

Auger

Exhaust

Air Intake

Auger Motor

Base

Hopper Lid

This manual is related to the following products: