Other digital input, Drive, En- en – Applied Motion ST10-Plus User Manual
Page 14

14
ST5/10-S Hardware manual
920-0027 Rev. D
2/7/14
Other Digital Input
As previously noted, the high speed STEP and DIR inputs are configured for 5V logic. EN is designed for opera-
tion between 5 and 12 volts DC. Add 1500 ohms to EN for 24V operation.
ST5-S
or
ST10-S
switch or relay
(closed=logic low)
EN-
EN+
5-12
VDC
Power
Supply
-
+
Drive
NPN
Proximity
Sensor
IN
COM
output
+
–
-
+
NPN
Proximity
Sensor
EN-
EN+
output
+
–
5-12
VDC
Power
Supply
-
+
Drive
PNP
Proximity
Sensor
IN
output
+
–
COM
-
+
PNP
Proximity
Sensor
EN+
output
+
–
EN-
5-12
VDC
Power
Supply
-
+