CARE AND MAINTENANCE

42

HYDROSTATIC PUMPS:

Before each use, check to be sure that the cooling fins
of the hydrostatic pumps are clean. Excessive accu-
mulation of oil, dirt, or trash may cause the pumps to
overheat. NEVER WASH ACROSS TOP OF RESER-
VOIR WITH WATER OR STEAM. Fill reservoir as
required per the maintenance schedule listed in this
book.

HYDROSTAT DRIVE BELT REPLACEMENT

PROCEDURE:

To remove hydrostat pump drive belt:

(The hydrostat pump drive is equipped with a spring
loaded belt take-up).

1. Raise seat.
2. Remove hold down bolts from belt cover. Remove

belt cover.

3. Rotate the spring loaded take-up idler towards the

left hand hydro pump to provide belt slack for re-
moval.

4. Remove belt.

To install hydrostat pump drive belt:

1. Rotate the spring loaded take-up idler

towards the left hand hydro pump.

2. Install belt per diagram.
3. Re-attach belt cover.
4. Return the seat to the

operating position.