beautypg.com

Lubrication, Troubleshooting, Lubricator drip rate settings – Nexen FMCE 625 801683 User Manual

Page 6

background image

6

FORM NO. L-20319-H-1112

LUBRICATION

1. Close and disconnect the air line from the unit.

2. Turn the Lubricator Adjustment Knob clockwise three

complete turns.

3. Open the air line.

4. Close the air line to the unit when a drop of oil forms in the

Lubricator Sight Gage.

5. Connect the air line to the unit.

6. Turn the Lubricator Adjustment Knob counterclockwise until

closed.

7. Turn the Lubricator Adjustment Knob clockwise one-third

turn.

8. Open the air line to the unit.

TROUBLESHOOTING

Female

Pilot

Plug

Housing

Splined

Disc

O-ring

Seals

Male

Pilot

Air

Chamber

Spring

Pin

Key

Ball

Bearings

Stub

Shaft

Piston

Set

Screw

Ball

Bearing

Air to

Clutch

Air to

Brake

Drive

Disc

Friction

Facings

Bar

Ball

Bearing

FIGURE 7

NOTE

Pneumatically actuated devices require clean, pressure regulated and lubricated air for maximum performance and long

life. The most effective and economical way to lubricate Nexen Clutch/Brakes is with an Air Line Lubricator, which injects

oil into the pressurized air, forcing an oil mist into the air chamber.

Locate the lubricator above and within ten feet of the Clutch/Brake, and use a low viscosity oil such as SAE-10.

Synthetic lubricants are not recommended.

LUBRICATOR DRIP RATE SETTINGS

NOTE

These settings are for Nexen supplied lubricators. If you are not using a Nexen lubricator, calibration must replicate the

following procedure.