Lubrication, Troubleshooting, Lubricator drip rate settings – Nexen FMCE 625 801683 User Manual
Page 6
6
FORM NO. L-20319-H-1112
LUBRICATION
1. Close and disconnect the air line from the unit.
2. Turn the Lubricator Adjustment Knob clockwise three
complete turns.
3. Open the air line.
4. Close the air line to the unit when a drop of oil forms in the
Lubricator Sight Gage.
5. Connect the air line to the unit.
6. Turn the Lubricator Adjustment Knob counterclockwise until
closed.
7. Turn the Lubricator Adjustment Knob clockwise one-third
turn.
8. Open the air line to the unit.
TROUBLESHOOTING
Female
Pilot
Plug
Housing
Splined
Disc
O-ring
Seals
Male
Pilot
Air
Chamber
Spring
Pin
Key
Ball
Bearings
Stub
Shaft
Piston
Set
Screw
Ball
Bearing
Air to
Clutch
Air to
Brake
Drive
Disc
Friction
Facings
Bar
Ball
Bearing
FIGURE 7
NOTE
Pneumatically actuated devices require clean, pressure regulated and lubricated air for maximum performance and long
life. The most effective and economical way to lubricate Nexen Clutch/Brakes is with an Air Line Lubricator, which injects
oil into the pressurized air, forcing an oil mist into the air chamber.
Locate the lubricator above and within ten feet of the Clutch/Brake, and use a low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
LUBRICATOR DRIP RATE SETTINGS
NOTE
These settings are for Nexen supplied lubricators. If you are not using a Nexen lubricator, calibration must replicate the
following procedure.