beautypg.com

Air connections (npt style) – Nexen FMCBE-70-14 801360 User Manual

Page 8

background image

(2)

FORM NO. L-20365-A-0699

4-WAY CONTROL VALVE

NOTE: Refer to Figure 3

1.

If the brake is to be set when the solenoid is de-
energized, connect Port 2 to the brake and Port 4 to
the clutch.

2.

Connect the air supply line to inlet Port 1.

5-WAY CONTROL VALVE

NOTE: Refer to Figure 4

1.

If the brake is to be set and the clutch is to be OFF
when the solenoid is de-energized, connect Port 4 to
the brake and the port marked 2 to the clutch.

2.

Connect the brake air supply line to Port 5 and the
clutch air supply line to Port 3.

3-WAY CONTROL VALVES

NOTE: Refer to Figure 5

1.

Install a 3-Way N.O. Control into the brake inlet port
and a 3-Way N.C. Control into the clutch inlet port.

2.

Connect the air supply line to the inlet port (marked
IN) on the top of the 3-Way N.O. Control and an air
supply line to the inlet port marked IN on the side of
the 3-Way N.C. Control.

FIGURE 3

FIGURE 4

FIGURE 5

3-Way N.O.

Control

Air to

Brake

Air to

Clutch

3-Way N.C.

Control

AIR CONNECTIONS (NPT Style)

NOTICE

For quick response, Nexen recommends a quick
exhaust valve and short air lines between the
Control Valves and the FMCBE. Align the air inlet
ports to the down position to allow condensation
to drain out of the air chambers. The Metric FMCBE
has ISO 7/1-Rc 1/8 ports.

NOTICE

When a 3-Way N.O. Control is de-energized, air flows
directly to the brake. When a 3-Way N.O. Control is
energized, air exhausts from the brake.

When a 3-Way N.C. Control is de-energized, air
exhausts from the clutch. When a 3-Way N.C. Control
is energized, air flows to the clutch.

This manual is related to the following products: