Danger – Nexen FMCBE-70-14 801360 User Manual
Page 10
(4)
FORM NO. L-20365-A-0699
DIN Connector; 9mm Centers
AIR AND ELECTRICAL CONNECTIONS (Integral Valve Style)
FIGURE 6
FIGURE 7
NOTE: Refer to Table 1 and Figures 6 and 7:
1.
Connect the air supply to the inlet port.
2.
Place the gasket on the Solenoid Valve (Item 36).
NOTE: If you do not install the gasket, you may not get
a proper seal. An improper seal can cause corrosion
in a moist environment.
3.
Plug the DIN Connector (Item 40) into the Solenoid
Valve (Item 36).
4.
Tighten the pan head screw included on the DIN
Connector (Item 40).
5.
Connect the lead wires of the DIN Connector (Item
40) to an appropriate power source (See Table 1).
Observe polarity when you connect any device
marked “+” and “-”.
Lead Wire Cable:
Brown wire = positive
White wire = common
Green wire = ground
NOTE: The 115 VDC rectified lead wire contains a full
bridge rectifier and surge suppressor which converts
AC power to rectified AC power and provides circuit
protection.
DANGER
Hazardous voltages.
Can cause severe injury or death.
Disconnect AC power prior to connecting wires.
Do not splice wires.
Conform to all applicable safety regulations and codes.
*
A Nexen rectifier lead wire is supplied for the 115 VDC
Table 1 - Spool Specifications
Current
Voltage
Resistance
Power
and can be used for AC (50/60 Hz) or DC operation.
Standard Coil:
115 VDC
*
2.5 Watts
5500 Ohms
.021 Amps
Optional Coils
(Contact Nexen)
24 VDC
0.6 Watts
1100 Ohms
.027 Amps
Solenoid
Part #
4919
4961
Item 40
Item 13
Item 36
12
Gasket
Solenoid
(Item 36)
DIN
Connector
(Item 40)
Pan Head Screw
Dynamco