AIR AND ELECTRICAL CONNECTIONS (Integral Valve Style)

FIGURE 6

FIGURE 7

NOTE: Refer to Table 1 and Figures 6 and 7:

1.

Connect the air supply to the inlet port.

2.

Place the gasket on the Solenoid Valve (Item 36).

NOTE: If you do not install the gasket, you may not get
a proper seal. An improper seal can cause corrosion
in a moist environment.

3.

Plug the DIN Connector (Item 40) into the Solenoid
Valve (Item 36).

4.

Tighten the pan head screw included on the DIN
Connector (Item 40).

5.

Connect the lead wires of the DIN Connector (Item
40) to an appropriate power source (See Table 1).
Observe polarity when you connect any device
marked “+” and “-”.

Lead Wire Cable:

Brown wire = positive
White wire = common
Green wire = ground

NOTE: The 115 VDC rectified lead wire contains a full
bridge rectifier and surge suppressor which converts
AC power to rectified AC power and provides circuit
protection.

DANGER

Hazardous voltages.

Can cause severe injury or death.

Disconnect AC power prior to connecting wires.

Do not splice wires.

Conform to all applicable safety regulations and codes.

*

A Nexen rectifier lead wire is supplied for the 115 VDC

Table 1 - Spool Specifications

Current

Voltage

Resistance

Power

and can be used for AC (50/60 Hz) or DC operation.

Standard Coil:

115 VDC

*

2.5 Watts

5500 Ohms

.021 Amps

Optional Coils

(Contact Nexen)

24 VDC

0.6 Watts

1100 Ohms

.027 Amps