Nexen QFB-2500 964086 User Manual
Page 7
FORM NO. L-20117-F-0210
7
NOTE
Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance and life.
All seals in Nexen Pneumatically operated devices are lubricated for life and do not require additional lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air, forcing an
oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air mist lubrication
system is used, it is continually used over the life of the product as the oil mist may wash free the factory
installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.
LUBRICATOR DRIP RATE SETTINGS
1. Close and disconnect the air line from the unit.
2. Turn the Lubricator Adjustment Knob counterclockwise three
complete turns.
3. Open the air line.
LUBRICATION
CAUTION
These settings are for Nexen supplied
lubricators. If you are not using a Nexen
lubricator, calibration must follow the
manufacturer's suggested procedure.
4. Close the air line to the unit when a drop of oil forms in the
Lubricator Sight Gage.
5. Connect the air line to the unit.
6. Turn the Lubricator Adjustment Knob clockwise until closed.
7. Turn the Lubricator Adjustment Knob counterclockwise one-
third turn.
8. Open the air line to the unit.
AIR CONNECTIONS
CAUTION
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.
The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.
NOTE
For quick response, Nexen recommends a quick
exhaust valve and short air lines between the
Control Valves and the product. Align the air inlet
ports to a down position to allow condensation to
drain out of the air chambers of the product.
- QFB-1150 964080 QFB-2500 964087 QFB-1150 964081 QFB-1150 964167 DFB-1650 964074 DFB-1650 964305 DFB-1650 964075 DFB-1650 964301 DFB-2200 964076 QFB-1650 964082 QFB-1650 964219 DFB-2200 964077 QFB-1650 964083 QFB-1650 964272 DFB-2500 964078 DFB-1150 964072 QFB-2200 964084 DFB-1150 964073 DFB-1150 964045 DFB-1150 964270 DFB-1150 964169 DFB-2500 964079 QFB-2200 964085 QFB-2200 964286 DFB-1150 964017 QFB-1150 964017 DFB-1650 964020 QFB-1650 964020 DFB-2200 964023 QFB-2200 964023 DFB-2500 964026 QFB-2500 964026