Nexen SSE-1000 822530 User Manual
Page 7
7
FORM NO. L-20175-J-1112
AIR CONNECTIONS
NOTE: Refer to Figure 4.
NOTE: The Restrictor is provided to prevent Shoulder
Bolt (Item 6) fatigue from impact during operation.
1. Connect Flexible Hose (Item 19) to the Restrictor
(Item 22) (See Figure 4).
NOTE: The Auxiliary Cooling Option has been removed
from all standard Nexen S, T and TSE series brakes.
It is a passage for compressed air to be connected for
increased thermal capacity. If you desire this feature
or are replacing a brake that has this feature, please
contact Nexen at 800-843-7445.
FIGURE 4
Restrictor
(Item 22)
CAUTION
Never operate brake without the
Restrictor installed.
NOTE
For quick response, Nexen recommends a quick exhaust
valve and short air lines between the Control Valves and
the product. Align the air inlet ports to a down position
to allow condensation to drain out of the air chambers
of the product.
CAUTION
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.
The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.
- SSE-450 818830 SSE-450 818829 SSE-450 818865 SSE-450 818866 SSE-600 820332 SSE-600 820366 SSE-600 820330 SSE-600 820334 SSE-600 820365 SSE-800 822431 SSE-800 822430 SSE-800 822465 SSE-800 822468 SSE-800 822432 SSE-800 822466 SSE-1000 822565 SSE-1000 822572 SSE-1000 822584 SSE-1000 822566 SSE-1000 822573