beautypg.com

Basic hardware set-up diagram – D-Link DCS-1000W User Manual

Page 12

background image

12

Basic Hardware Set-up Diagram

The diagram below shows the hardware configuration for 1 Active Sensor (PIR Motion

Sensor), 1 Passive Sensor (Magnetic Switch), and 1 output (For Relay) for a siren.

Passive Component Notes!!!

Only simple magnetic or contact switches can be used for Passive components. This

limitation is by the camera only supplying 5V and less then 100mA current to those

circuits. Distance for passive components is limited by a viewable camera range of about

25 Ft using 26GA wire.

Active Component Notes!!!

A separate power supply is needed for these devices. In order to choose the proper PS.

The total current draw by all the components cannot exceed the Max supplied by the

power supply.

Example

Our PIR Motion Detector = 17 mA = .017A

Our Relay = 60 mA = .06A

Siren = 200mA = .20A

Total : .277A

Purchased DC power adapter 12V DC 1.2A Max to cover all Active Sensors and Siren,

with room to grow.