Adjusting the spin down/up timer, Figure 10: device spin down/up timer switch – StorCase Technology S20A102 User Manual

Page 21

background image

StorCase Technology, Inc.

S20A102 User's Guide - Rev. A01

14

Installation

Front of

Receiving

Frame

0143

0 2

4

6

8

A

C

E

0 = 10 SECONDS

8 = 50 SECONDS

1 = 15 SECONDS

9 = 55 SECONDS

2 = 20 SECONDS

A = 60 SECONDS

3 = 25 SECONDS

B = 65 SECONDS

4 = 30 SECONDS

C = 70 SECONDS

5 = 35 SECONDS

D = 75 SECONDS

6 = 40 SECONDS

E = 80 SECONDS

7 = 45 SECONDS

F = 85 SECONDS

Spin Down/Up Time

Figure 10: Device Spin Down/Up Timer Switch

Adjusting the Spin Down/Up Timer

The timer for device spin down is controlled by a small selector, located in a cutout on the side

of the DE100 receiving frame as shown in Figure 10. When the key is turned to the OFF position,

and when the timer receives a NO SCSI Activity signal from the Isolator Board, it waits the

specified delay time before displaying a “u” on the front panel of the receiving frame. The

amount of time required for a disk drive to spin down is approximately 15 seconds or more.

This number can vary depending on the type of SCSI device and manufacturer (e.g. a Seagate

Barracuda may require 45 seconds). The factory configuration is set for 20 seconds. A

different delay time may be selected with the provided alignment tool. Refer to the SCSI device

manufacturer’s manual for more information on required device spin down time.