Adjusting the spin down/up timer, Figure 10: device spin down/up timer switch – StorCase Technology S20A102 User Manual
Page 21
StorCase Technology, Inc.
S20A102 User's Guide - Rev. A01
14
Installation
Front of
Receiving
Frame
0143
0 2
4
6
8
A
C
E
0 = 10 SECONDS
8 = 50 SECONDS
1 = 15 SECONDS
9 = 55 SECONDS
2 = 20 SECONDS
A = 60 SECONDS
3 = 25 SECONDS
B = 65 SECONDS
4 = 30 SECONDS
C = 70 SECONDS
5 = 35 SECONDS
D = 75 SECONDS
6 = 40 SECONDS
E = 80 SECONDS
7 = 45 SECONDS
F = 85 SECONDS
Spin Down/Up Time
Figure 10: Device Spin Down/Up Timer Switch
Adjusting the Spin Down/Up Timer
The timer for device spin down is controlled by a small selector, located in a cutout on the side
of the DE100 receiving frame as shown in Figure 10. When the key is turned to the OFF position,
and when the timer receives a NO SCSI Activity signal from the Isolator Board, it waits the
specified delay time before displaying a u on the front panel of the receiving frame. The
amount of time required for a disk drive to spin down is approximately 15 seconds or more.
This number can vary depending on the type of SCSI device and manufacturer (e.g. a Seagate
Barracuda may require 45 seconds). The factory configuration is set for 20 seconds. A
different delay time may be selected with the provided alignment tool. Refer to the SCSI device
manufacturers manual for more information on required device spin down time.