beautypg.com

Appendix b - factory-installed options, Isolator/repeater board, Bus-isolating hot swap function – StorCase Technology DE100i-SWCU2 User Manual

Page 25: Repeater function

background image

StorCase Technology, Inc.

DE100i-SWCU2 User's Guide - Rev. B02

18

Appendix B - Factory-Installed Options

Appendix B - Factory-Installed Options

Isolator/Repeater Board

The Isolator/Repeater Board (Figure B-1) is an upgrade attachment for the DE100i-SWCU2

receiving frame. This attachment provides a bus-isolating repeater function as described

below.

Bus-Isolating Hot Swap Function

The Isolator/Repeater Board (P/N DX1/200-SWC160/RH) provides an enhanced, bus-isolating

hot swap function by allowing the installation, removal or exchange of DE100i-SWCU2 carriers

while your computer system is operating by monitoring and protecting the computer system

and other peripheral devices on the SCSI Bus. The Isolator Board eliminates the need to shut

down the system when adding or removing a SCSI device by performing two functions:

1.

Delays power up/down of the drive until the time period between SCSI bus cycles.

This prevents the interruption of any SCSI bus activity by other devices on the bus.

2.

Prevents drive power sequencing from generating noise on the SCSI bus, thus

preventing data transfer corruption on other devices.

Please note that, whereas UNIX and Apple-based systems provide mount/dismount drive

commands, most PC systems do not provide such a feature. When using one of these operating

systems, it may be necessary to reboot the computer after adding or changing a drive. This

reboot activity will force the SCSI host adapter to rescan its SCSI bus for physically attached

drives, and will then be able to access the new or changed drive.

Repeater Function

All StorCase

®

Technology SCSI removable enclosures adhere strictly to SCSI specifications.

These products are typically installed into storage system configurations which contain a

variety of components (such as cables, terminators, and connectors), which may have

varying SCSI characteristics when used together in some configurations.

The StorCase Data Express

®

Repeater Board has been shown to resolve issues associ-

ated with combining system components designed for different SCSI technologies (single-

ended or LVD) and/or by different manufacturers.

Your configuration may require that a Data Express Repeater Board be installed

on the product’s receiving frame.

For more information and data, please refer to the Repeater Board Benefits and Downward

Compatibility technical papers on our web site at: http://www.storcase.com/tools