StorCase Technology DE100i-SWCU2 User Manual
Page 17
10
Installation
StorCase Technology, Inc.
DE100i-SWCU2 User's Guide - Rev. B02
NOTE:
Option Pins 15-18 (Table 2) are used to remotely access the disk drive's
motor control options. Refer to the documentation provided by the drive
manufacturer for further information.
Open
Open
Motor spins up on "Power On"
Open
Closed
Motor spins up only if SCSI
"Start" command is received
Closed
Open
Drive motor starts spinning up
approximately 12 seconds x the
SCSI ID number for each target
drive (12 second minimum)
Closed
Closed
Reserved
Closed = Jumper installed
Open = Jumper removed
DLYD_START RMT_START
Function
1
ID0
SCSI ID
2
GND
Ground
3
ID1
SCSI ID
4
GND
Ground
5
ID2
SCSI ID
6
GND
Ground
7
ID3
SCSI ID
8
GND
Ground
9
RLEDC
Remote LED Cathode
10
RLEDA
Remote LED Anode
11
Reserved
12
Reserved
13
SYNC
Drive Synchronous Signal
14
GND
Ground
15
RMT_START
Remote Start (see Table 2)
16
GND
Ground
17
DLYD_START
Delay Start (see Table 2)
18
GND
Ground
19
DFAULT
Force Drive Fault Signal to Display
20
GND
Ground
21
WRTPT
Force Drive Write Protect to Display
22
GND
Ground
Table 1: Option Pin Signal Descriptions
Table 2: Option Pins 15-18 Drive Motor Control
PIN
Signal
Function