Speck Electronics SSM User Manual
Page 19

Chapter 3 Installation Section
There are five terminals available on the power transformer of the power
supply. The configuration of the five terminals determines the operating
voltage of the power supply. It is only necessary to change the black
(line) and white (neutral) AC wires. Do not attempt to remove or
change the Green AC safety wire or the multicolored wires used at the
DC terminals. It is recommended that you measure the DC voltages at
the circular DC connector before reconnection to the mixer.
The following chart represents the proper AC terminal configuration for
the Model PS3-1.5 power supply.
The following chart represents the proper fuse rating for the
Model PS3-1.5 power supply. All fuses are 3AG Slow-Blow type.
AC wiring chart
14
Fuse chart
FOR USE AT:
JUMPER AT:
APPLY AC AT:
120 VAC
1 & 3
2 & 4
4 & 1
220 VAC
2 & 3
1 & 5
230 VAC
2 & 3
4 & 1
240 VAC
2 & 3
4 & 1
120 VOLTS AC
220 VOLTS AC
230 VOLTS AC
240 VOLTS AC
1 AMP
.5 AMP
.5 AMP
.5 AMP
CAUTION!
ALWAYS CHECK THE PROPER OPERATING
VOLTAGE BEFORE OPERATING THE SSM.
CAUTION!
DO NOT REMOVE, DEFEAT, OR DISABLE THE
SAFETY EARTH TERMINAL ON THE POWER
CORD. DO NOT USE A GROUND LIFT ON THE
POWER SUPPLY.