Specifications, Control ranges, 14 specifications – Sonnox Oxford Dynamics User Manual
Page 47: 1 control ranges, Sidechain eq
14 SPECIFICATIONS
14 Specifications
14.1 ControlRanges
Section Thresh Ratio/Range Attack
Hold
Release
(dB)
(dB)
GATE
-80 - 0
0 - -80
5 µS
[1]
- 26 mS
10 mS - 10 S 7.8 - 519 mS
EXP
-60 - 0
0 - -80
0.26 - 104 mS
10 mS - 10 S 7.8 - 519 mS
COMP
-60 - 0
1:1 - Limit
519 µS - 52 mS
10 mS - 30 S 52 mS - 3.1 S
LIM
-60 - 0
100 µS - 500 mS 50 mS - 30 S 100 mS - 10 S
Note:
[1]
All values in the table are referenced to full scale and time constants apply to a 10
dB gain change. Thus the time value marked
[1]
denotes a calculated value for 10 dB
gain change, since the true figure is 40 dB gain change in 20.8µS (1 sample at 48
kHz).
SidechainEQ
LF
20 Hz - 1 kHz
HF 500 Hz - 20 kHz
Q
0.5 - 16, or shelving
Gain
+/- 20 dB