beautypg.com

页 18, System setting, Item selection description – SkyRC B6AC+ V2 Charger User Manual

Page 18

background image

SYSTEM SETTING

S a f e t y T i m e r
O N 1 2 0 M i n

R e s t T i m e
C H G > D C H G 1 0 M i n

C a p a c i t y C u t - O f f
O N 5 0 0 0 m A H

T e m p e r a t u r e U n i t
C e l s i u s

T e m p C u t - O f f
O N 5 0 ° C 1 2 2 ° F

This program sets the maximum charge
capacity that will be supplied to the battery
during charge. If the delta peak voltage is
not detected nor the safety timer expired by
any reason, this feature will automatically
stop the process at the selected capacity
value.

When you start a charge process, the
integral safety timer automatically starts
running at the same time. This is
programmed to prevent overcharge the
battery if it proves to be faulty, or if the
termination circuit cannot detect the battery
full. The value for the safety timer should be
generous enough to allow a full charge of
the battery.

The battery's internal chemical reaction will
cause the temperature of the battery to
rise. If the temperature limit is reached, the
process will be terminated.

OFF/
ON
(

100-50000 mAh)

It will be operated with the default value of the essential user settings when it is powered
on for the first time.The screen displays the following information in sequence and the
user can change the value of parameter on each screen.
When you are willing to alter the parameter value in the program, press START/ENTER to
make it blink then change the value with INC or DEC. The value will be stored by
pressing START/ENTER once.

ITEM

SELECTION

DESCRIPTION

OFF/
ON
(

1-720 Min

)

OFF/
ON
(20 C/68 F -
80 C/176 F

)

Celsius
Fahrenheit

1-60Min

A rest time allowing the battery to cool
down between charging/discharging cycle.

You can choose the temperature displayed
by Celsius or Fahrenheit as you like.

· 16

B6AC+ V2