页 12, Operating program, It is for lithium battery in all mode – SkyRC B6AC+ V2 Charger User Manual
Page 12
Failure to connect as shown in this diagram will damage this charger.
To avoid short circuit between the charge lead always connect the charge cable to the
charger first, then connect the battery. Reverse the sequence when disconnecting.
WARNING:
OPERATING PROGRAM
Here is the detailed procedure to make the charger work. All the screens and operations
will take Li-Po BALANCE CHARGE program for example,
1. Connection
Connecting to power source
SKYRC B6AC+ V2 comes with the built in switching power supply. You can connect
the AC power cord directly to the main AC socket. (100-240V AC).
Connecting the battery
Important!!! Before connecting a battery it is absolutely essential to check one last
time that you have set the parameters correctly. If the settings are incorrect, the
battery may be damaged, and could even burst into flames or explode. To avoid
short circuits between the banana plugs, always connect the charge leads to the
charger first, and only then to the battery. Reverse the sequence when
disconnecting the pack.
Balance Socket
The balance wire attached to the battery must be connected to the charger with the
black wire aligned with the negative marking. Take care to maintain correct polarity!
(See the wiring diagram below.)
This diagram shows the correct way to connect your battery to the SKYRC B6AC+
V2 while charging in the balance charge program mode.
1).
2).
3).
It is for lithium battery in all mode.
· 10
B6AC+ V2