LUBRICATION
For maximum performance and tool life, an air line lubricator, set to deliver 4 drops per minute, is recommended. SIOUX No. 288 Air Motor Oil is
recommended.
If an airline lubrication is not used, it is recommended that the tool be oiled daily before use to improve performance. Add 2-4 drops of air motor oil and
run the tool for 10-20 seconds to distribute oil through the tool.
Lubricate through the grease fitting with Castrol Molub-Alloy 860/460-2ES after 100 hours of operation.
MAINTENANCE
Water, dust and other airline contaminants can cause rust and vane sticking. For long periods between tool use, flush the tool with 5 ml of oil and run for
10 seconds. This will help remove contaminants and reduce the formation of rust.
DISMANTLING & ASSEMBLY INSTRUCTIONS
Disconnect tool from air supply. Remove Hex. Bolt (22) then Screw (39) by using a screw driver. Loosen screws (14) by using a Screw driver. Remove
hammer case (1), o-ring (34), spring bushing (33) and pull out trigger (53). Loosen Hex. Bolts (37) and remove rear bearing plate (30), rotor (28) and
blades (27). Remove spring pin by using a hammer with a small pin. Use a wrench to loosen air inlet (52). Remove exhaust deflector (49), spring (47).
Remove hammer frame (7) from hammer case (1), remove gasket (8), pull out hammer pins (5), turn around anvil (4) and remove hammers (6).
REASSEMBLY
Clean and examine all parts for wear and replace any parts with parts obtained from manufacturer or authorized distributor. All parts must be dry.
Check that all bearings run smoothly and reassemble all tool parts in reverse order. Pump grease by using a mini grease gun into the grease fitting (9) .
Connect tool to a suitable air supply (90 psi preferred) and run tool slowly for 5 seconds to allow the grease to circulate
WARNING
Disconnect tool from air supply before performing any adjustment, maintenance, or repair.
NOISE AND VIBRATION READINGS
Catalog
Number
Noise* (Tested in accordance with ISO Standard 15744)
Vibration* (Tested in accordance with
ISO Standard 28927-1:2009)
*Sound Pressure (dBA)
*Sound Power (dBA)
Uncertainty (dBA)
*Vibration m/s^2
Uncertainty m/s^2
IW750MP
98.9
109.9
3
19.86
2.44