INSTRUCTIONS AND PARTS LIST FOR 1410R, 1410AR, & 1412R AIR DRILLS
SERIAL “C”
Read and understand "Safety Instructions For Air Tools" and these instructions before
operating this tool.
AIR SUPPLY
The efficiency of the tool is dependent on the proper supply of clean dry air at 90 psig (6.2 bar). The use of a line filter, pressure
regulator, and lubricator will insure maximum output and service life of tools.
HOSE AND HOSE CONNECTIONS
Supply hose should be not less than 5/16" (7.9mm) I.D. Extension hoses should be at least 3/8" (10mm) I.D. Use couplings and
fittings with at least 5/16" (7.9mm) I.D.
LUBRICATION
An airline lubricator, set to deliver one drop per minute, is recommended. If a lubricator is not used, add .04oz. (1.2cc) of SIOUX No.
288 air motor oil into the air inlet daily.
Lubricate the gearing with SIOUX No. 1232A grease after every 50 hours of operation.
GENERAL OPERATION
This tool is equipped with a teasing throttle. By slightly depressing the trigger the chuck will rotate slowly. This is useful for starting a
drill bit without first spotting with a punch. Fully depressing the trigger for maximum speed.
A speed control adjusting screw is located on the trigger face and is adjusted with a 1/16” (1.6mm) hex key wrench.
SOUND AND VIBRATION READINGS
Sound Pressure
Sound Power
Vibration
Catalog No.
dBA
dBA
m/s
2
1410R
73.2
85.1
Less than 2.5
1410AR
73.2
85.1
Less than 2.5
1412R
73.2
85.1
Less than 2.5
*prt PN8NTC1
*prt PN8NTC1
*per ISO8662
Tools left connected to the air supply while making adjustments, changing accessories, or doing any mainte-
nance or service on tool can start unexpectedly.
Always remove tool from air supply and activate trigger to bleed air line before making any adjust-
ments, changing accessories, or doing any maintenance or service on tool.
Tools starting unexpectedly can cause injury.
DECLARATION OF CONFORMITY
We, Sioux Tools Inc., 250 Snap-on Drive, P.O. Box 1596, Murphy, NC, 28906, USA, declare under our sole responsibility that the products
1410R, 1410AR, and 1412R
to which this declaration relates are in conformity with the following standard or standards or other normative document or documents:
EN 792 (draft), EN 292 Parts 1&2, ISO 8662, Pneurop PN8NTC1
following the provisions of
89/392/EEC as amended by 91/368/EEC & 93/44/EC Directives.
June 1, 2003
Murphy, North Carolina, USA
Date and place of issues
Gerald E. Seebeck
President
Sioux Tools Inc.