Remy REPLACING DELCO REMY 24SI ALTERNATATORS User Manual
Page 2

Technical support: USA 800 854 0076, Mexico 01 800 000 7378, Brazil 0800 703 3526, South America 55 11 2106 6510 or visit
delcoremy.com
NOTICE
- Only licensed Remy International, Inc. product and component parts should be used, and the use of other parts or modifications not approved
by Remy International, Inc. will void all applicable warranties. The failure to carefully follow these Installation Instructions, set forth above, will void all
applicable warranties. DELCO REMY is a registered trademark of General Motors Corporation, licensed to Remy International, Inc. Pendleton, IN 46064.
©
2012 Remy International, Inc. All rights reserved
2
GROUND SCREW
[LOCATION WILL VARY]
5.6-6.8 Nm (50-60 lb in)
21SI & 22SI REMOTE SENSE 2-TERMINAL REGULATOR
21SI, 22SI & 23SI NON-REMOTE SENSE
(23SI TERMINAL LOCATIONS VARY)
GROUND (-)
(LOCATION
WILL VARY)
GROUND (-)
(LOCATION
WILL VARY)
PHASE (RELAY)
INDICATOR LAMP
EXTERNAL FIELD MONITOR
REMOTE SENSE (OPTIONAL)
DESCRIPTIONS OF ALTERNATOR TERMINALS (See illustrations):
“BAT” Output (+) - Output terminal, connects to the Positive (BAT) Battery terminal to charge the batteries.
“P” Phase (Relay) - Relay terminal carries half system voltage and may be used for certain types of control relays, charge indicators,
tachometers or similar devices. The current draw should not exceed four (4) amperes. Notice! Do not connect the remote sense lead
to this terminal.
“L” Indicator Lamp - Indicator Lamp terminal can take up to 1 Amp Lamp Current.
Field Monitor - External Field Monitor is only used for diagnostics.
“GRD” Screw - Grounds the alternator. A Ground lead is strongly recommended for optimum performance.
“Remote Sense™” Terminal – Remote Voltage Sense (if equipped) used to more accurately control system voltage by monitoring
actual voltage at Battery Terminal or Junction Block. Notice!
Be careful not to ground the lead’s open end, because the line is always
live “hot”.
OUTPUT TERMINAL (+)
9.0-13.0 Nm (80-120 lb in)
INDICATOR/IGNITION
REMOTE SENSE
(OPTIONAL)
22SI REMOTE SENSE
4-TERMINAL REGULATOR
OUTPUT (BAT)
GROUND (-)
OUTPUT (+)
RELAY
INDICATOR/IGNITION
RELAY
OUTPUT (+)
USE PULLEY FROM OLD ALTERNATOR
IF IN OPERABLE CONDITION (SEE
PULLEY INSTRUCTIONS)
24SI ALTERNATOR
PHASE (RELAY)
INDICATOR LAMP
EXTERNAL FIELD MONITOR
REMOTE SENSE (0PTIONAL)
NOTICE! DO NOT INSTALL EXTERNAL FAN ON 24SI ALTERNATOR
NOTICE! USE ON Clock-Wise APPLICATIONS ONLY (viewing pulley side of alternator)