Specifi cations – RODE Microphones NT6 User Manual
Page 3

- 3 -
Specifi cations
Acoustic
Principle:
Pressure gradient
Directional
Pattern:
Cardioid (see graph)
Frequency
Range:
40Hz-20kHz, selectable HPF @
80Hz/12dB/octave (see graph)
Output
Impedence:
200
Sensitivity:
-37 dB re 1 Volt/Pascal (16 mV @
94 dB SPL) +/- 2 dB @ 1kHz
Equivalent Noise:
19 dB SPL (A - weighted per
IEC651)
Maximum
Output:
+6dBu (@ 1kHz, 1% THD into
1K load)
Dynamic Range:
119 dB (per IEC651, IEC268-15)
Maximum SPL:
135dB SPL
(@ 1kHz, 1% THD into 1K load)
(145dB with maximum PAD)
Signal/Noise:
75 dB SPL
(A - weighted per IEC651)
Power
Requirement:
P48 (48V), P24 (24V) phantom
supply
Output
Connection:
3 pin XLR, balanced output
between pin 2(+), pin (-) & pin 1
(ground)
Net Weight:
386gm