SUNTUF® Technical Guide
Profile: Iron 76/18 (Sinus)
26/02/2009
2
Positioning
Make sure the UV protected side faces out.
Side-lap of SUNTUF panels must be installed against the primary direction of rain.
The SUNTUF panels must be located and installed without any stresses.
Do not pull, stretch or force the sheets when the profiles are not perfectly matched.
Fastening
Apply sealing tape over the SUNTUF panel side-lap corrugation crests, where covered
by the next panel.
Apply sealing tape along the bottom and top End-lap (if there is), along screws
centerline or two tapes on both sides of screw centerline.
Pre-drill 10mm holes at crests where screws are positioned.
Start fastening the screws from the first side-lap (left) through the pre-drilled holes (3).
Start fastening the screws on the lower edge purlin (End-lap), through every other
corrugation crest (1).
Fasten screws at the internal purlins, through every third corrugation crest, starting at
the same side (2).
Fasten screws at the upper edge purlin, through every other corrugation crest, starting
at the same side (1).
Do not over-tighten!
• Fasten the stitching screws at every 300 mm (4).
Fastening Location
1)
2)
3) 4)
Screws and Washers Specification
Crest fixing: Self-drilling 5.5mm (¼") x 40mm (1½") screw + matched metal crest rider
(Storm washers) with EPDM gasket or 19mm diameter- galvanized / aluminum /
stainless metal washer attached to EPDM rubber gasket of 55 to 65 shore hardness.
Side Stitching: 5.5mm x 19mm (3/4”) self-tapping screw with 19 mm washer/gasket.