Maintenance – DeVillbiss Air Power Company D26968 User Manual

Page 16

background image

16- ENG

D26968

Note 1: Change oil after first two (2) operating hours and every 50 operating
hours thereafter, more often if operated in extreme dusty or dirty conditions.

Note 2: Check oil after 5 hours of operation.

CUSTOMER RESPONSIBILITIES TABLE

MAINTENANCE TASK

Before

each

use

Every 25

Hours of

Every

Season

Every 50

Hours of

Every

Season

Every 100

Hours of

Every

Season

Check Spark Plug

Prepare unit for storage if it is to remain
idle for more than 30 days.

MAINTENANCE

Check oil level

Change oil

Clean Air Filter Assembly

Prepare Unit for Storage

See Note 2

X

See Note 1

X

X

X

GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been subjected to
operator abuse or negligence. To receive full value from the warranty, operator
must maintain the generator as instructed in this manual.

ENGINE MAINTENANCE

Refer to the Engine Operator's manual for service and maintenance of the
engine.

4.

Voltage sensitive equipment should be the last equipment connected to the
generator. Plug voltage sensitive appliances such at TV's, VCR's, micro-
waves, ovens, computers, and cordless telephones into a UL listed voltage
surge protector, then connect the UL listed voltage surge protector to the
generator.

Failure to connect and operate equipment in this sequence
can cause damage to equipment and will void the warranty

on your generator.

Follow the wattage calculation table in the Wattage Calculation section of
this manual. Overloading the generator will cause power fluctuations and
can damage equipment and appliances.

DeVilbiss Air Power Company will only be responsible for damage to
customer's equipment when the generator is determined to be defective.
This determination will only be made by an authorized representative of
DeVilbiss Air Power Company and this decision will be final. DeVilbiss Air
Power Company reserves the right to inspect the electrical connections at
the customer's site of operation and test the generator for proper opera-
tion before any determination of liability is made. Failure to maintain the
equipment or wiring for inspection will void any claim for damages by the
customer. DeVilbiss Air Power Company will not be responsible for
equipment damaged as a result of voltage surges, improper operation or
improper installation of the generator.