Ntellisys, Hrottling, Utterfly – Nor-Cal Intellisys Throttling Butterfly Valve User Manual
Page 5: Alves, 0 - device specification - general
![background image](/manuals/740020/5/background.png)
4
4
Visit our Web Site
www.n-c.com
TBV-OP-LIT 01/04
I
NTELLISYS
T
HROTTLING
B
UTTERFLY
V
ALVES
5
Call toll free
800-824-4166
or 530-842-4457
•
FAX 530-842-9130
TBV-OP-LIT 01/04
I
NTELLISYS
T
HROTTLING
B
UTTERFLY
V
ALVES
2.0 - Device Specification - General
The following figures and tables summarize specifications of the TBV-series product. UVD-series products share the specifications except those that are marked
by an asterisk (
*
).
TABLE 2.0.1 –GENERAL EQUIPMENT SPECIFICATIONS
FEATURE
SPECIFICATION
*
Dimensions
Refer to Figures 2.1 and 2.2, as well as Tables 2.3 and 2.4
*
Weight, in lbs (kg)
Refer to Tables 2.3 and 2.4
Rated Input
2A, 2.25
Ω (only to be operated by Nor-Cal Products APC controller models)
Rated Output Torque
Refer to Tables 2.3 and 2.4
Actuation Speed
125 msec open to closed for direct drive valves (-D)
250 msec open to closed for gear driven valves (-G)
Position Resolution
1:204,800 steps (equivalent to 1.6 arc seconds) for direct drive valves. Finer resolution for gear driven valves,
depending on the exact gear ratio.
*
Leak Rate
1 × 10
-9
atm·scc/sec He
*
Allowable Plate Differential Pressure
15 psi (103.4 kPa)
*
Heating Capabilities
Body can be heated up to 392ºF (200ºC) with optional heater kits. Note that certain other components such as the
Viton seals and motor-to-valve coupling may need to be replaced with alternate materials when the temperature
exceeds 248ºF (120ºC).
Protection Class
I
Degree of Protection (IP)
X0
Laser Class
1 (LED’s)
Certifications
CE Standard for Process Equipment including EMC Directive 89/336/EC and Machinery Directive 89/392/EEC
Maximum Altitude
6562 ft (2000 m)
Allowable Ambient Operating Temperature
32ºF – 122ºF (0ºC - 50ºC)
Allowable Ambient Humidity
0 – 95% non-condensing
Installation Clearance
For IQ-series TBVs and UVDs 3” (75 mm) is required on all perforated sides. Otherwise, a minimum
of 3
1
/
2
” (90 mm) is needed on top to allow for connector(s).
*Not applicable to UVD-series products
TABLE 2.0.2 – TBV RELIABILITY
SPECIFICATION
COMMENTS
*
MTBF
> 2 million cycles or > 11,500 hours
Processes with large amounts of effluent contamination or highly aggressive chemistries may reduce the MTBF due to
condensation on moving parts and/or O-ring degradation.
*
Warranty
1 year
*Not applicable to UVD-series products