beautypg.com

Set the closed position limit, For pull-to-open installation, Step 1 – Mighty Mule MM402 User Manual

Page 26: Step 2, Step 3, Step 4, Step 5, Step 6, Step 7

background image

16

Mighty Mule FM402 Installation Instructions

rev 082211

Set the CLOSED Position Limit

for PULL-TO-OPEN Installation

Your transmitter must be able to operate the gate. If not, see "Personalize Your Transmitter Setting" on page 18.
Note: The OPEN limit is when the opener is fully retracted and the gate is in the full open position. The open limit setting

can only be adjusted by moving the gate bracket. To achieve the optimum closed position, you must adjust the CLOSED

limit setting:

Step 1

Make sure the Control Box is ON and that

the gate is in the OPEN POSITION (arms fully

retracted).

Step 2

Press and HOLD the 2nd Opener CLOSE

button on the control board and be prepared

to RELEASE the button when the gate reaches

the desired closed position/limit. Use the JOG

OPEN and CLOSE buttons to "fine tune" the

gate position if neccessary.

Step 3

Press and HOLD the 1st Opener CLOSE button

on the control board and be prepared to RELEASE the button when the gate reaches the desired closed position/limit.

Use the JOG OPEN and CLOSE buttons to "fine tune" the gate position if neccessary.

Step 4

With the gates in in the desired closed positions PRESS and HOLD the SET LIMIT button until the alarm and RED Light

come on. Then release the button.

NOTE: The opener must be extended more than 7 inches to set limits.

Step 5

NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet.
Press the transmitter button once (within 5 feet of the control board) and allow the gates to fully open. The alarm will beep

once when both gates reach the OPEN LIMIT. This indicates the limits for both arms are programmed in memory.

Step 6

Press the transmitter button and allow the gates to fully close to verify that they stop at the desired positions. Repeat

Steps 2-5 if correction is needed.

SURGE PROTECTOR

Transformer

MIN

MAX OFF

REMOVE JUMPER FOR

PUSH TO OPEN OPTION

120

SEC.

STALL FORCE

OPEN < JOG > CLOSE

PWR.

SET

LIMIT

1st OPR.

2nd OPR.

STATUS

AUTO CLOSE

FIRST Opener

JOG Buttons

SET LIMIT Button

SET LIMIT Light

SECOND Opener

JOG Buttons

Step 7

Plug the transformer into the electrical outlet. Use of a surge protector

with the transformer is

strongly recommended. If electrical outlet is

located outdoors, outlet and transformer should be protected by a

weatherproof cover.