Troubleshooting guide, Audible feedback – Mighty Mule FM500 Blue Board User Manual
Page 37

34
Troubleshooting Guide
If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department.
Audible Feedback
Symptom
Diagnosis
Check:
1 short beep upon
activation
Blown Fuse
Low or Bad Battery
Loose Battery Connection
• Fuse
• Battery Under Load
• Battery Harness Connections
1 short beep upon
power up
Circuit Board Powered
Up & Ready
• Normal Operation
Continuous
Uninterrupted Alarm
Circuit Board Senses an
Obstruction
• Path of Gate
• Gate for Level and Plumb
• Stall Force Adjustment
• Disconnect Safety Devices
• Rev Counter
1 beep with 10 seconds
off
Low Battery Condition
• Fuses
• Battery Harness Connections
• Battery Under Load
1 beep then 2 beeps
Master Motor Terminals
Shorted
• Connections to Master Inputs
• Master Arm Power Cable
• Motor
• Circuit Board
1 beep then 3 beeps
Slave Motor Terminals
Shorted
• Connections to Master Inputs
• Master Arm Power Cable
• Motor
• Circuit Board
1 beep with 2 seconds
off
Master Arm Limit Switch
Error
• Connections to Master Inputs
• Master Arm Power Cable
• Master Input ORG & GRN, BRN & GRN voltage with
wires disconnected. 11VDC across each terminal.
2 beeps with 2 seconds
off
Slave Arm Limit Switch
Error
• Connections to Slave Inputs
• Slave Arm Power Cable
• Slave Input ORG & GRN, BRN & GRN voltage with
wires disconnected. 11VDC each across each terminal.
3 beeps with 2 seconds
off
Master Arm Rev Counter
Error
• Connections to Master Inputs
• Master Arm Power Cable
• Rev Counter
4 beeps with 2 seconds
off
Slave Arm Rev Counter
Error
• Connections to Master Inputs
• Master Arm Power Cable
• Rev Counter