beautypg.com

Troubleshooting guide, Audible feedback – Mighty Mule FM500 Blue Board User Manual

Page 37

background image

34

Troubleshooting Guide

If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department.

Audible Feedback

Symptom

Diagnosis

Check:

1 short beep upon
activation

Blown Fuse
Low or Bad Battery
Loose Battery Connection

• Fuse
• Battery Under Load
• Battery Harness Connections

1 short beep upon
power up

Circuit Board Powered
Up & Ready

• Normal Operation

Continuous
Uninterrupted Alarm

Circuit Board Senses an
Obstruction

• Path of Gate
• Gate for Level and Plumb
• Stall Force Adjustment
• Disconnect Safety Devices
• Rev Counter

1 beep with 10 seconds
off

Low Battery Condition

• Fuses
• Battery Harness Connections
• Battery Under Load

1 beep then 2 beeps

Master Motor Terminals
Shorted

• Connections to Master Inputs
• Master Arm Power Cable
• Motor
• Circuit Board

1 beep then 3 beeps

Slave Motor Terminals
Shorted

• Connections to Master Inputs
• Master Arm Power Cable
• Motor
• Circuit Board

1 beep with 2 seconds
off

Master Arm Limit Switch
Error

• Connections to Master Inputs
• Master Arm Power Cable
• Master Input ORG & GRN, BRN & GRN voltage with
wires disconnected. 11VDC across each terminal.

2 beeps with 2 seconds
off

Slave Arm Limit Switch
Error

• Connections to Slave Inputs
• Slave Arm Power Cable
• Slave Input ORG & GRN, BRN & GRN voltage with
wires disconnected. 11VDC each across each terminal.

3 beeps with 2 seconds
off

Master Arm Rev Counter
Error

• Connections to Master Inputs
• Master Arm Power Cable
• Rev Counter

4 beeps with 2 seconds
off

Slave Arm Rev Counter
Error

• Connections to Master Inputs
• Master Arm Power Cable
• Rev Counter