beautypg.com

LINK Systems OmniLink 5000 User Manual

Page 9

background image

2-4

entering the password the user must switch the Program/Run key to the PROG position.

Section 2.3.5 Die Protection Restricted Items

The following table lists the die protection restricted items name and function.

DIE PROTECTION RESTRICTED ITEMS

NAME

FUNCTION

DP Bypass

Bypass the Die Protection

DP Reset

Reset the Die Protection

DP Settings

Change the Die Protection type, settings, and name.

Section 2.3.6 Access Control Operation

To gain access control the user must use one of two means or a combination of these two means.
These means are the Program/Run key or the user password system.

Section 2.3.6.1 Program/Run Key Switch Operation

The Program/Run key switch is located on the lower right side of the operator terminal. This is a
two position switch. The key is removable in the RUN position only. If the Program/Run key
switch is being used as a means to access the restricted items, the switch must be turned to the PROG
position. When the Program/Run key switch is switched to the PROG position, the press will Top
Stop and stroking will be prohibited until the switch is returned to the RUN position.

When operating in the Key Only mode the key switch is the only means available to access the
restricted items. All restricted items are accessible when the Program/Run key switch is switched
to the PROG position.

When operating in the “Key or Password” mode, the key switch is one of the means available to
access the restricted items. All restricted items are accessible when the Program/Run key switch is
switched to the PROG position.

When operating in the “Key and Password” mode, the key switch and password must be used to
access the restricted items. In this mode, the user will be granted access only to the restricted items
that have been assigned to him.

When the Program/Run switch is in the Program position, the softkeys highlighted in Figure 2.1 will