For Fiberglass Blowers


Fiberglass Blowers model numbers 7180000 through 7180700,
feature a 10-3/4" ID outlet connection. Ten-inch diameter
ductwork will slip into this connection and should be held by sheet
metal screws through the housing. Silicone sealant should be used
to seal any air leaks between the duct and blower outlet
connection.

Fiberglass Blowers model numbers 7180800 through 7181700,
feature a 12-3/4" ID outlet connection. Twelve-inch diameter
ductwork will slip into this connection and should be held by sheet
metal screws through the housing. Silicone sealant should be used
to seal any air leaks between the duct and blower outlet
connection.

Fiberglass Blowers model numbers 7182000 through 7182300,
feature a 16" ID outlet connection. Sixteen-inch diameter
ductwork will slip into this connection and should be held by sheet
metal screws through the housing. Silicone sealant should be used
to seal any air leaks between the duct and blower outlet
connection.

For PVC Blowers


PVC Blower, model number 7183000, features a 10-3/4" ID outlet
connection. Ten-inch diameter ductwork will slip into this
connection and should be held by sheet metal screws through the
housing. Silicone sealant should be used to seal any air leaks
between the duct and blower outlet connection.

PVC Blowers, model numbers 7183100 and 7183200, feature a 12-
3/4" ID outlet connection. Twelve-inch diameter ductwork will
slip into this connection and should be held by sheet metal screws
through the housing. Silicone sealant should be used to seal any
air leaks between the duct and blower outlet connection.

Connect to the Electrical Supply

Source


The electrical connection for the Coated Steel Blower is made
directly at the motor. Remove the end plate from the motor and