beautypg.com

Appendix 36, 5 signal flow and vpl to output measurements – Lab.gruppen C Series 5:4X User Manual

Page 43

background image

C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4

Appendix

36

6.5 Signal flow and VPL to output measurements

The table below shows the block signal flow of the C...X Series amplifiers, as well as a table providing output
power based on the settings of the rear panel VPL DIP-switches.

Figure 7.5: C...X Series signal flow and VPL to output settings

VPL Set to 100 V peak

Sensitivity:

Gain

dBu

Vrms

1.2

0.9

+38 dBu

4.2

1.3

+35 dBu

7.2

1.8

+32 dBu

10.2

2.5

+29 dBu

dBu

Vrms

W1)

W2)

+38

0.9

250

125

+35

1.3

250

125

+32

1.8

250

125

+29

2.5

121

121

1) For C 10:4X / C 20:8X in 4 ohms

2) For C 5:4X / C 10:8X in 4 ohms

1.2
4.2
7.2

10.2

VPL Set to 63 V peak

Sensitivity:

Gain

dBu

Vrms

-2.8

0.6

+38 dBu

0.2

0.8

+35 dBu

3.2

1.1

+32 dBu

6.2

1.6

+29 dBu

VPL Set to 45 V peak

Sensitivity:

Gain

dBu

Vrms

-5.7

0.4

+38 dBu

-2.7

0.6

+35 dBu

0.3

0.8

+32 dBu

3.3

1.1

+29 dBu

VPL Set to 32 V peak

Sensitivity:

Gain

dBu

Vrms

-8.7

0.3

+38 dBu

-5.7

0.4

+35 dBu

-2.7

0.6

+32 dBu

0.3

0.8

+29 dBu

This manual is related to the following products: