6.4 Current Draw and Thermal Dissipation specification
The following tables contain information on measured current consumption as well as calculated heat dissipa-
tion during normal operation(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
C 20:8X
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal Dissipation
120 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby w. remote Power Off via NomadLink
6
0
6
20
5
Power On, Idling
91
0
91
312
79
Amp
Watt
Pink noise
(1/8)
70 V / Ch.
250
x8
4,8
2,5
546
250
296
1011
255
16 Ω / Ch.
250
x8
4,2
2,2
486
250
236
807
203
32 Ω / Bridged
500
x4
100 V / Ch.
500
x4
3,6
1,9
418
250
168
573
144
8 Ω / Ch.
250
x8
3,5
1,8
399
250
149
509
128
16 Ω / Bridged
500
x4
4 Ω / Ch.
250
x8
3,4
1,8
376
250
126
431
109
8 Ω / Bridged
500
x4
2 Ω / Ch.
125
x8
2,3
1,2
259
125
134
459
116
4 Ω / Bridged
250
x4
Pink noise (1/4) 70 V / Ch.
250
x8
7,4
3,9
785
500
285
972
245
16 Ω / Ch.
250
x8
7,3
3,8
782
500
282
961
242
32 Ω / Bridged
500
x4
100 V / Ch.
500
x4
6,7
3,5
774
500
274
937
236
8 Ω / Ch.
250
x8
6,7
3,5
772
500
272
928
234
16 Ω / Bridged
500
x4
4 Ω / Ch.
250
x8
6,5
3,4
743
500
243
830
209
8 Ω / Bridged
500
x4
2 Ω / Ch.
125
x8
3,8
2,0
435
250
185
632
159
4 Ω / Bridged
250
x4
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
Table 7.4a: C 20:8X Current Draw and Thermal Dissipation specifications