C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4

Appendix

34

C 10:4X

Level

Load

Rated power

Line Current *2)

Watt *1)

Thermal Dissipation

120 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby w. remote Power Off via NomadLink

6

0

6

20

5

Power On, Idling

51

0

51

312

79

Amp

Watt

Pink noise
(1/8)

70 V / Ch.

250

x4

2,7

1,4

274

125

149

509

128

16 Ω / Ch.

250

x4

2,5

1,3

252

125

127

432

109

32 Ω / Bridged

500

x2

100 V / Ch.

250

x4

2,0

1,0

225

125

100

341

86

500

x2

8 Ω / Ch.

500

x2

2,1

1,1

217

125

92

314

79

16 Ω / Bridged

4 Ω / Ch.

250

x4

2,3

1,2

230

125

105

359

90

8 Ω / Bridged

500

x2

2 Ω / Ch.

125

x4

1,3

0,7

136

63

73

249

63

4 Ω / Bridged

250

x2

Pink noise
(1/4)

70 V / Ch.

250

x4

4,9

2,6

526

250

276

942

237

16 Ω / Ch.

250

x4

4,3

2,2

458

250

208

710

179

32 Ω / Bridged

500

x2

100 V / Ch.

500

x2

3,3

1,7

384

250

134

456

115

8 Ω / Ch.

250

x4

3,5

1,8

364

250

114

388

98

16 Ω / Bridged

500

x2

4 Ω / Ch.

250

x4

3,6

1,9

373

250

123

421

106

8 Ω / Bridged

500

x2

2 Ω / Ch.

125

x4

2,2

1,1

219

125

94

321

81

4 Ω / Bridged

250

x2

*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and

specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.

Table 7.4c: C 10:4X Current Draw and Thermal Dissipation specifications