15. Appendices

28

IPD SERIES Operation Manual rev 1.0.0

15.2. Thermal dissipation charts

Model - IPD 2400

IPD 2400

Level

Load

Rated power

Mains

voltage

Line

current

Watt *1)

Thermal Dissipation

VAC

IAC *2)

In

Out

Dissipated

BTU/hr

kCal/hr

Standby w. remote Power Off.

230

0.088

7.10

0

7

24

6

120

0.0981

6.45

0

6

22

6

100

0.11

6.45

0

6

22

6

Power on, Idling

230

0.229

28.20

0

28

96

24

120

0.383

29.20

0

29

100

25

100

0.44

27.40

0

27

94

24

Pink Pseudo
Noise (1/8)

16 Ω / Ch.

300

x 2

230.0

1.1

127

75

52

178

45

120.0

1.7

127

75

52

177

45

100.0

1.8

114

75

39

134

34

8 Ω / Ch.

600

x 2

230.0

1.9

218

150

68

233

59

120.0

3.0

229

150

79

270

68

100.0

3.8

239

150

89

303

76

4 Ω / Ch.

1200

x

2

230.0

3.3

431

300

131

448

113

120.0

5.3

455

300

155

530

133

100.0

6.1

451

300

151

514

129

2 Ω / Ch.

800

x 2

230.0

2.3

279

150

129

439

111

120.0

3.4

260

150

110

376

95

100.0

4.1

258

150

108

368

93

*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here

is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw figures measured at 230 V. as well as 120 V. The efficiency is similar, but not identical for the two scenarios. The efficiency for 100 V mains is

very similar to that of 120 V.