beautypg.com

Setting up and modifying amplifier groups, Intellidrive controller overview – Lab.gruppen IPD 2400 User Manual

Page 20

background image

20

IPD SERIES Operation Manual rev 1.0.0

These tabs are:

i. To Recall a preset from the Device, select the preset from the drop-down menu and click/tap on

operation. (See Section 10.3)

ii. Levels - Presents facilities for setting input and output levels, setting limiters, and allows an option for

linking channels to duplicate settings. (See Section 10.4)

iii. Input EQ (1 & 2) - Presents facilities for setting parameters for the 10-band parametric input EQ.

(See Section 10.5)

iv. X-Over (Crossover) - Presents facilities for setting high- and low-pass filters for precise signal division.

(See Section 10.7)

v. Output EQ (1 & 2) - Presents facilities for setting parameters for the 10-band output parametric EQ.

Note: In Two-Way Mode, the Output EQ will show the settings of the Crossover filters.

(See Section 10.6)

10. IntelliDrive Controller Set-up and DSP Configuration

10.1. Setting up and modifying amplifier groups

Amplifiers on the network may be set up in groups to allow easier monitoring of status and simultaneous
configuration grouped amplifiers.

Note: There is no group master control panel. When a group is formed, any change in any amplifier’s Mixer control
panel will affect all amplifiers in the group, with resulting changes in functions and parameters determined by the
specific group configuration.

Creating a new group - From Global View, at top right corner click/tap New Group button. Enter a name for the
group and click/tap Okay. The new group will appear in Global View.

Setting up and modifying an existing group - In Global View, click/tap the SET-UP button for the group. This
opens the Configure Group window.

1. Select desired Group Status

a. When Group is Enabled, any changes will affect units in the Group as determined by Group Type.

When Disabled, any changes affect only the individual amplifier unit selected.

2. Select Group Type

a. Carbon Copy - Parameters changed on any amplifier in the Group will apply to all other amplifiers in the

Group by default. If exceptions are desired, click on Exceptions. In the Select Exceptions window,

Active Links will be displayed. Use the drop-down tabs to add or remove parameters to be linked within

the Group.

b. Advanced Configuration - Click on Setup Links. Active Links in the Group will be displayed. No

parameters will be linked by default. Use the drop-down tabs to select any parameters to be linked

within the Group. Drop-down tab functions are (top to bottom):

i. Amplifier/DSP functions

ii. Function dependent: filter number if PEQ or All selected; input number if Mixer selected

iii. Inputs and outputs

iv. Function dependent: parameters if filter selected; On and Gain if Mixer selected

9. IntelliDrive controller overview

This manual is related to the following products: