HITEC X1 AC Plus: Single Port AC/DC Chargers User Manual
Page 31

31
Lithium
Additional Features & Settings
The Temperature Cut-off is turned on or off with the use of the optional
temperature probe by contacting the surface of the battery. If it is on, set the
maximum temperature that the charger should allow the battery to reach dur-
ing charging. Once the battery reaches this temperature, the process will be
terminated to prevent damage to the battery.
See pg. 28 for instructions on accessing the “
Temp Cut-
off
“ screen.
Press the
► button once and “
Temp Cut-off
“ will begin fl ashing.
Use the ✚ or
▬ buttons to toggle between
Temp Cut-off
and
USB Enable.
While “
Temp Cut-off
“ is fl ashing, the
► button again and the temperature
value will begin fl ashing. Use the ✚ or ▬ buttons to change the temperature
value. This value can be set between 20ºC and 80ºC.
Press
► to set the Temperature Cut-off .
During the charge>discharge or discharge>charge cycle, batteries increase in
temperature. The Waste Time program allows the user to specify the time delay
between cycles, allowing time for the battery to cool.
See pg. 28 for instructions on accessing the “
Waste Time
“ screen.
Press the
► button once and the timer value will begin
fl ashing. Use the ✚ or ▬ buttons to adjust the timer
value. The timer can be set to 0 to 60 minutes.
Press
► to set the Waste Timer.
USB Temperatre Cut-off
Waste Time
USB/Temp Select
Temp Cut-off 80C
Waste Time
CHG>DCHG 1min