Hanna Instruments HI 9026V User Manual
Page 2

2
3
Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the instrument.
This manual will provide you with the necessary information for correct use of the
instrument, as well as a more precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail us at
[email protected] or contact the nearest technical office.
This instrument is in compliance with the
directives.
WARRANTY
All Hanna Instruments meters are warranted for two years against defects in workmanship
and materials when used for their intended purpose and maintained according to instructions.
Electrodes and probes are warranted for six months.
This warranty is limited to repair or replacement free of charge. Damages due to accidents, misuse,
tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instrument. If under war-
ranty, report the model number, date of purchase, serial number and the nature of the failure.
First obtain a Returned Goods Authorization number from the Customer Service department, then
return the instrument with the Authorization # included along with shipment costs prepaid. If the
repair is not covered by the warranty, you will be notified of the charges. When shipping any
instrument, make sure it is properly packaged for complete protection.
TABLE OF CONTENTS
PRELIMINARY EXAMINATION
GENERAL DESCRIPTION
Remove the kit from the packing material and examine it to make sure that no
damage has occurred during shipping. If there is any damage, notify your
dealer or the nearest Hanna Customer Service Center.
The kit includes:
• HI 9026 waterproof pH meter with Cal-Check
TM
• HI 1048B double junction, refillable pH electrode
• HI 7662 stainless steel temperature probe
• pH 3.00 and pH 7.01 buffer solutions, 20 mL each
• HI 700635 and HI 700636 specific cleaning solutions, 20 mL each
• HI 7082 electrode refilling solution (30 mL) and syringe
• 100 mL plastic beaker
• 1.5V AA alkaline batteries (4 pcs)
• instruction manual
• rugged carrying case.
Note: Save all packing material until you are sure that the instrument
functions correctly. All defective items must be returned in the original
packing with the supplied accessories.
PRELIMINARY EXAMINATION ..................................................................... 3
GENERAL DESCRIPTION ............................................................................. 3
FUNCTIONAL DESCRIPTION ....................................................................... 4
SPECIFICATIONS ........................................................................................ 5
OPERATIONAL GUIDE ................................................................................ 6
SETUP MENU ........................................................................................... 9
CALIBRATION .......................................................................................... 10
pH BUFFER TEMPERATURE DEPENDENCE ................................................... 14
LCD MESSAGE GUIDE ............................................................................... 15
TROUBLESHOOTING GUIDE ..................................................................... 16
BATTERY REPLACEMENT ........................................................................... 16
pH ELECTRODE MAINTENANCE ................................................................. 17
ACCESSORIES .......................................................................................... 19
HI 9026 is an advanced pH/ORP meter specifically designed to provide affordable
and very precise results under harsh industrial conditions. The meter also features
a backlit display for clear readings in the darkest environments.
You can choose from 7 memorized buffer values (pH 1.68, 4.01, 6.86, 7.01,
9.18, 10.01 and 12.45) for pH calibration. In addition, the user can program
2 custom buffer values, in order to best fit the characteristics of the sample.
For example, if you are going to measure wine and must, you can enter the pH
3.00 buffer value for calibration.
When calibration is complete, the electrode condition is displayed, so the user
can be sure the electrode is working properly or that it needs to be cleaned or
replaced.
The supplied HI 1048B electrode features the innovative CPS
TM
(Clogging
Prevention System), ideal for pH measurements in wine and must.
With proper electrodes, HI 9026 can also measure ORP with a resolution up to
0.1 mV.