Hanna Instruments HI 8014 User Manual
Page 14
26
27
FC210B
Glass body, double junction, conic, Viscolene, non-
refillable combination pH electrode. Use: milk, yogurt.
FC220B
Glass body, triple ceramic, single junction, refill-
able, combination pH electrode. Use: food processing.
FC911B
PVDF body, double junction, refillable with built-
in amplifier, combination pH electrode. Use: very high
humidity.
HI1413B
Glass body, single junction, flat tip, Viscolene,
non-refillable combination pH electrode. Use: surface.
ORP ELECTRODES
HI3131B / HI3111S
Glass body, refillable, combination plati-
num ORP electrode. Use: titration.
HI3230B / HI3210S
Plastic body, gel-filled, combination plati-
num ORP electrode. Use: general purpose.
HI4430B / HI4410S
Plastic body, gel-filled, combination gold
ORP electrode. Use: general purpose.
EXTENSION CABLES (SCREW TO BNC CONNECTOR)
HI 7855/1
Extension cable 1 m (3.3') long
HI 7855/3
Extension cable 3 m (9.9') long
OTHER ACCESSORIES
ChecktempC Pocket-size thermometer (range -50.0 to 150.0°C)
HI 710001
Soft carrying case for HI 8014 and HI 8915
HI 710004
Soft carrying case for HI 931000
HI 710007
Shockproof, blue rubber boot for HI 931000
HI 710008
Shockproof, orange rubber boot for HI 931000
HI 710009
Shockproof, blue rubber boot (for HI8014 and HI8915)
HI 710010
Shockproof, orange rubber boot (for HI8014 and
HI8915)
HI 710031
General-purpose rugged carrying case
HI 721311
Rugged carrying case for HI 8014 and HI 8915 with
pH 4.01 and pH 7.01 solutions and screwdriver
HI 731326
Calibration screwdriver (20 pcs.)
HI 7669AW Temperature probe with 1 m (3.3') cable, for HI 8915
HI 8427
pH and ORP electrode simulator with 1 m (3.3')
coaxial cable ending in female BNC connectors
HI 931001
pH and ORP electrode simulator with LCD and 1 m
(3.3') coaxial cable ending in female BNC connectors
CE DECLARATION OF CONFORMITY
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which
they are used. Operation of these instruments in residential areas could cause unacceptable interfer-
ences to radio and TV equipment.
The glass bulb at the end of the electrode is sensitive to electrostatic discharges. Avoid touching this
glass bulb at all times. During operation, ESD wrist straps should be worn to avoid possible damage to
the electrode by electrostatic discharges.
Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC
performance. To avoid electrical shock, do not use these instruments when voltages at the measure-
ment surface exceed 24 Vac or 60 Vdc.
In particular cases HI 8915 could change its operating mode. In such cases, press any key to return to
normal operating conditions.
To avoid damages or burns, do not perform any measurement in microwave ovens.