HDMI, VGA/YPbPr, and Serial over Single Fiber

7

Data Rate

OM1
(62.5/125 µm )

OM2
(50/125 µm )

OM3
(50/125 µm )

1.65 Gb/s
(HDMI 1.2a)

250 m (820 ft)

500 m (1640 ft)

1000 m (3280 ft)

3.4 Gb/s
(HDMI 1.3, 1.4)

150 m (500 ft)

250 m (820 ft)

500 m (1640 ft)

The above table shows the maximum possible cable lengths based on data
rates for 1080p resolution with normal 8-bit color per HDMI 1.2a, as well
as deep color per HDMI 1.3 or 1.4, versus different cable constructions.
The max specified distances disregard inter-pair skew. A maximum inter-
pair skew of 0.6 * Tpixel (as required by HDMI specifications) would
limit the max distance to 600 meters regardless of cable construction at
1080p resolution. However, most HDMI equipment can tolerate skews
larger than that.

5.4 Status of LED Indicators

PWR:

Solid GREEN –Unit is in operation.

OFF – Unit is off or not operational.

LINK:

Solid RED – Optical link has been established between
the sender and the receiver.

OFF – Optical link has not been established between the
sender and the receiver.

SOURCE:

Solid GREEN – Source detected on the sender.

OFF – No source detected on the sender.
(Note that for Source #3 VGA input, due to the built-in
Converter, the source LED will be lit regardless of
connection of VGA input)

HPD:

Solid RED – Hot plug detect is active (there is a monitor
plugged to the remote unit and/or it is turned on).

OFF – No hot plug detect is present (there is no LCD
connected to the remote, or it is off).

VIDEO:

Solid GREEN – There is TMDS clock (digital video is
coming from Source)

OFF – Source is not outputting digital video.
(Note that for Source #3 VGA input, due to the built-in
Converter, the source LED will be lit regardless of
connection of VGA input)

This manual is related to the following products: