beautypg.com

6 rs-232 control commands, Hdmi, vga/ypbpr, and serial over single fiber 17 – Hall Research HR-733-S User Manual

Page 19

background image

HDMI, VGA/YPbPr, and Serial over Single Fiber

17

6.6 RS-232 Control Commands

All commands are prefixed with ==>
All commands and responses are followed with a carriage return
Wrong commands will get a response of ERR1

Command:

SCn stands for input Source Channel where n=(0-3,?). (0 =
Blank, 1= HDMI#1, 2 = HDMI#2, 3 =VGA/YPbPr, ? = query input)

Response:

SCn

Command:

PLn stands for front Panel Lock where n=(0-1,?). (0 = unlocked, 1
= locked, ? = query lock status)

Response:

PLn

Command:

SBn stands for Set Baud of remote unit where n=(0-7,?). (0 =
1200, 1 = 2400, 2 = 4800, 3 = 9600, 4 = 19200, 5 = 38400, 6 =
57600, 7 = 115200, ? = query baud rate)

Response:

SBn

Condition:

This command can only be executed when the fiber-optic data
channel is configured for RS-232. If this command is issued in CEC
mode the front panel will show a notice to change to RS-232 mode,
and the serial port response will be
ERR2

Command:

SPn stands for Set Parity of remote unit where n=(0-2,?). (0 =
none, 1 = odd, 2 = even, ? = query Parity)

Response:

SPn

Condition:

This command can only be executed when the fiber-optic data
channel is configured for RS-232. If this command is issued in CEC
mode the front panel will show a notice to change to RS-232 mode,
and the serial port response will be
ERR2

Command:

DCn stands for Data Channel configuration where n=(0,1,?). (0 =
RS-232, 1 = CEC, ? = query Parity)

Response:

SPn

Command:

FD stands for Factory Default –factory default settings will be
restored. This may take as long as 7 seconds

Response:

FD

Command:

FW? stands for Firmware Version query

Response:

FW Version #