3.0 Setup

3.1 Package Contents

All UHBX-3S units are shipped with +5V power supply, a 1m HDMI cable and

a male-to-female RS-232 cable.

3.2 Installation











Figure 3 – UHBX-3S Application Diagram

As shown in the diagram above, UHBX-3S is used to extend a single video

source to three (3) remote displays, located within 500 ft (150 m) from the

source. It also provides an additional HDMI output for connection to a local

display or for daisy chaining to another UHBX-3S for more HDBaseT outputs.

When the UHBX-3S is used with UHBX-R-PD receivers, the RS-232 and Power

(PoH) signals are also extended on the same Cat 6 cable. The RS-232 In port is

used to send/receive commands or data to/from remote displays connected at the

output. Special RS-232 commands are provided to selectively communicate with

any individual output (Please refer to Section 5 for more details.).
Note: By default the output port numbers are assigned address 1 through 3. If

RS-232 ports are daisy chained among several UHBX-3S devices then the user

must assign different port numbers to each box so each HDBaseT output has a

unique address. In order to do this the user must connect each additional box to a

PC using the supplied using a USB cable (cable is type A to mini-USB) and

utilize the "UHBX-3S Manager Software" available for download from Hall

Research website.
Multiple UHBX-3S boxes can be daily-chained together as shown below.

UHBX-R-PD

UHBX-R-PD

UHBX-R-PD

Remote

Display 1

Remote

Display 3

Video

Source

PC

Cat 6

Cat 6

Cat 6

Remote

Display 2

+5V

+48V

Local

Display

HDMI Cable

RS-232 Cable

USB

Mini

USB

HDMI

In

HDMI

Out

2

1

3

RS-232

In (F)

RS-232

Out (M)

UHBX-3S

USB is only required

to assign Output port

numbers & to manage

EDID.