beautypg.com

1 general – Glow-worm Hideaway 40CF User Manual

Page 5

background image

5

221807B

Diagram 1.1

GENERAL DIMENSIONS - given in millimetres (Approx. inches)

RANGE RATING

HIDEAWAY 40

NOMINAL

kW

HEAT INPUT
(GROSS)

Btu/h

11.25

13.05

14.87

38,400

44,530

50,740

min

medium

max

BURNER

mbar

SETTING
PRESSURE

in.w.g

(HOT)

6.5

8.7

11.0

2.6

3.5

4.4

NOMINAL

kW

HEAT
OUTPUT

Btu/h

8.79

10.26

11.72

30,000

35,000

40,000

K7218

1 General

A

B

C

D

E

F

G

H

J

K

L

M

N

mm

300

118

598

294

265

533

3

300

445 121

88

900

115

in.

11

3

/

4

4

5

/

8

23

1

/

2

11

1

/

2

10

1

/

2

21

1

/

8

11

3

/

4

17

1

/

2

4

3

/

4

3

1

/

2

35

1

/

2

4

1

/

2

INJECTOR

Sheet Metal Parts

Warning. When installing or servicing this boiler care should be
taken when handling sheet metal parts, to avoid the possibility
of personal injury.

Important Notice

This boiler is for use only on G20 gas.

Wherever possible, all materials, appliances and components
to be used shall comply with the requirements of British
Standards.

Where no British Standards exist, materials and equipment
should be fit for their purpose and of suitable quality and
workmanship.

1.1 Data

Approx.weight of boiler: 76kg (168 lb)

Water content:

5.76litre (1.27 gal)

Gas connection:

Rc

1

/

2

(

1

/

2

BSP)

Water connection:

Rc1 (1inch BSP)

Electrical supply:

240V - 50Hz fused at 3A

Burner:

Aeromatic

The Seasonal Efficiency Domestic Boilers UK (SEDBUK) is
70.8%.

The value is used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.

1.2 Range Rating

This boiler is range rated and may be adjusted to suit individual
systems. The table gives settings and outputs.

The boiler input is supplied preset to maximum and should be
adjusted to suit system requirements.

WATER CONNECTIONS
Rc1 (1in. B.S.P.T.)

INSIDE DIAMETER OF
SOCKET FOR 100mm (4in.)
NOMINAL DIAMETER FLUE
TO BS567

WATER CONNECTIONS Rc1
reduced with DISTRIBUTOR
TUBE to Rc

3/

4

(

3/

4

in. B.S.P.T.)

(pumped return)

GAS CONNECTION

Rc

1/

2

(

1/

2

in. B.S.P.T.)

A SPECIAL TOP CASING
TO SUIT 600mm (23

5/

8

in.)

WORKTOPS IS AVAILABLE

0993

F (MIN)

D

FLUE

C

E

B

C

L

A

M

C

L

L (MIN)

G
(MIN)

J (MIN)

H

N

*

FLUE

K

(MIN)

1.3 Statutory Requirements

The installation of this boiler must be carried out by a competent
person in accordance with the relevant requirements of the
current issue of:

Manufacturer’s instructions, supplied.

The Gas Safety (Installation and Use) Regulations, The Building
Regulations, Local Water Company Byelaws, The Building
Standards (Scotland) Regulations, applicable in Scotland, The
Health and Safety at Work Act, The Control of Substances
Hazardous to Health, The Electricity at Work Regulations and
any applicable local regulations.

Detailed recommendations are contained in the current issue of
the following British Standards and Codes of Practice:

BS6798, BS5440 Part 1 and 2, BS5449, BS6700, BS6891,
BS5546, BS7478, BS7593, BS7671.

Manufacturer’s instructions must not be taken as overriding
statutory requirements.