beautypg.com

5 casing location / fitting, 6 electrical wiring – Glow-worm Hideaway 40CF User Manual

Page 11

background image

11

221807B

MAINS INLET CONNECTOR

Diagram 6.1

0878

N E

L

COVER

CABLE
CLAMP

LUGS

SLOTS

SIDE CASINGS FITTING

Diagram 5.2

1018

LOCATING
LUG AND
SLOT

No. 8
SCREW (2)

No. 8
SCREW (2)

CASING
BRACKET

CASING
BRACKET

BOILER
PLINTH

5 Casing Location / Fitting

5.1 Side Vent Grille

One vent grille is supplied with the boiler which can be fitted at
the rear of the left or right hand side casing. The grille is fitted
on the opposite side to any pipework connections.

Fit the grille, if required, to the side panel as shown in diagram
5.1 prior to fixing the side panel. The plastic pegs are a tight fit
and are best pushed home with a flat faced tool.

Do not use the grille if water connections are on both sides of the
boiler or if the boiler is screened by fixtures.

5.2 Side Casings

Fit side casing by locating their lugs into the lower slots in the
base tray, see diagram 5.2.

Secure the casing sides to the casing bracket at the front top.

6.1 Control Box Cable Connection

Remove the screw and cover from the mains inlet connector,
see diagram 6.1.

Using heat resistant flexible cable of suitable length and rating,
as Section 1.6, connect the cable to the terminals in the
connector. Secure the outer sheathing with the clamp.

Engage slots and lugs, replace connector cover and secure
with screw.

Connect mains inlet connector to the control box and use three
of the cable clips, supplied loose, pushed on to the edge of the
left hand panel in positions “CB” as shown in diagram 6.2 to
make sure that the cable does not touch any hot surfaces.

6.2 Circulation Pump Cable Connection

Heat resistant cable with a rating as stated in Section 1.6 must
be used for all wiring near the boiler, including the pump, if within
the boiler casing.

Support the pump cable away from hot surfaces if within the
boiler casing by pushing two cable clips, supplied loose, on to
the top edge of one side casing, as shown as “P” or “AP” in
diagram 6.2.

6 Electrical Wiring

SIDE VENT GRILLE

Diagram 5.1

SIDE VENT GRILLE
(If required, will fit to
left or right side casing)

PLASTIC PEG

SIDE CASING
(R.H. SHOWN)

0885