REMOVAL OF BURNER FROM
COMBUSTION CHAMBER

8 Servicing

Diagram 8.5

BURNER SERVICING

Diagram 8.6

1033

8.2 Burner and Injector

Follow instructions to remove the front cover, burner and controls
assembly as Section 8.1.

Remove the screw securing the lint arrester gauze to the
combustion chamber cover. Remove arrester by lifting slightly
and withdrawing forwards to clear gas pipe, thermocouple and
pilot tube, see diagram 8.5.

Remove the two burner securing nuts from the flange of the
burner supply pipe.

Remove the burner from the cover and supply pipe flange.

Slacken the nut securing the locking slide on the venturi right
side, disengage the slide to enable the venturi end of the burner
to be twisted anticlockwise to disengage it from the burner body,
see diagram 8.6.

Clean the burner parts and lint arrester thoroughly, using a
vacuum cleaner.

Check the condition of the burner gasket. Reuse or replace the
gasket as necessary. Reassembly by locating the venturi lugs
into the burner slots and twisting clockwise, see diagram 8.6.

Check the main burner injector for blockage or damage and
replace as necessary, see Section 9.2.

When replacing lint arrester locate the two lugs into the slots on
the combustion chamber cover and locate around the feed pipe,
then secure with the screws.

8.3 Service Checks

Inspect the pilot burner, thermocouple and pilot burner, cleaning
as necessary. Check the condition of the parts. If necessary
remove the pilot shield by removing the securing screw and nut.

Check the condition of the side and rear insulation panels in the
combustion chamber.

Check the condition of the seals on the cleaning door and the
combustion chamber cover.

Replace all items in the reverse order, relight and test the boiler.

Replacement of parts should be carried out by a competent
person.

SECURING
SCREW

LINT
ARRESTER

LUG

SECURING
NUT(2)

PROTECTIVE
SLEEVING

SLOT

MAIN
BURNER

INJECTOR

COMBUSTION
CHAMBER
COVER

1013

BURNER
SUPPLY
PIPE

Locate venturi
lugs in burner
slots and twist
clockwise to
engage

BURNER
BODY

BURNER
GASKET

NUT

LOCKING
SLIDE

VENTURI

Twist VENTURI
anti-clockwise
to disengage
from BURNER
BODY

Diagram 8.8

6126

BAFFLES

HEAT
EXCHANGERS

HEAT EXCHANGERS

Diagram 8.7

6122

BAFFLE