System design, Solar system, Compartment or cupboard installations – Glow-worm Clearly Solar Controller User Manual
Page 5: Fluropro solar control

5
These instructions are an integral part of the controller and
must, to comply with the current issue of the Gas Safety
(Installation and Use) Regulations, be left with the user.
Please ensure that the installer has fully completed the
Benchmark Checklist in the centre pages of the installation
instructions supplied with the product and that you have
signed it to say that you have received a full and clear
explanation of its operation. The installer is legally required
to complete a commissioning checklist as a means of
complying with the appropriate Building Regulations
(England and Wales).
All installations must be notified to Local Area Building
Control either directly or through a Competent Persons
Scheme. A Building Regulations Compliance Certificate
will then be issued to the customer who should, on receipt,
write the Notification Number on the Benchmark Checklist.
Please read these instructions and follow them carefully for
the safe and economical use of this product.
Solar system
The solar system is intended for the provision of solar he-
ated domestic hot water. Any other use is considered to be
improper and the manufacturers / suppliers are not liable for
any resulting damage.
IMPORTANT: We accept no liability for any damage or inju-
ries caused by improper use.
System Design
Flurocyl twin coil unvented cylinder
The Flurocyl is an unvented, indirectly heated hot water
cylinder for use with solar systems and suitable boilers.
This cylinder is intended to supply domestic hot water and
may only be used for this purpose.
Compartment or Cupboard Installations
Ventilation is not required for compartment or cupboard
installations. Do not use the compartment or cupboard for
storage.
Fluropro solar control
The Fluropro monitors the temperature within your cylinder
and solar panel and controls the solar system accordingly.
This control is also able to determine if the boiler is
required to provide further heat.
The Fluropro solar control works on the principal of
differential temperature control. The control always
switches on the collector pump when the difference in
temperature (collector temperature - cylinder temperature)
is greater than the programmed activation difference.
The controller switches off the collector pump when the
difference in temperature (collector temperature - cylinder
temperature) is less than the programmed deactivation
difference.