Operating the controller
The Fluropro solar control is similar to use as the
Glow-worm Climapro programmable room thermostat
by allowing the user to scroll through options and
settings menus via a single button, multi press function.
Adjustments are made to the control settings by pressing
the
and
buttons.
Special functions are accessed and activated by pressing
the
button.
Installer and service menus must only be accessed by
service or installation engineers.
Operation
Fluropro Cylinder Reheat Programmer
The Fluropro incorporates a 7 day programmer for timing
the domestic hot water cylinder reheat. Utilising this
programmer also ensures that your boiler will only be fired
when absolutely necessary, maximising solar gain and
minimising gas consumption.
When using the Fluropro DHW programmer, the domestic
hot water channel of any existing programmer is not used.
The Fluropro control will only signal to the boiler if the
cylinder is below the required temperature, if the solar
system is not operating and if the programmer is on.
Alternative DHW Programmer
However there are circumstances when the Fluropro
domestic hot water programmer cannot be used due to
installation limitations or where the householder is familiar
with an existing domestic hot water programmer and does
not want to revert to the Fluropro programmer. In such
cases an alternative DHW programmer can be used.
NOTE: Programme the alternative domestic hot water
programmer to provide hot water when required. Consider
carefully when the solar system might be running and try
to time to HW programmer to run when there is unlikely to
be any solar gain.
NOTE: The Fluropro will only control the solar system.