Maintenance, 13 trouble-shooting, 14 servicing – Glow-worm Clearly Hybrid - Compact Hydraulic Module HB User Manual
Page 13: 15 replacement of parts, 16 technical data

0020096881_02 - 08/10 - Glow-worm
- 11 -
MAINTENANCE
MAINTENANCE
13 Trouble-shooting
The following checks should be performed before proceeding
onto specific diagnostics:
- Make sure that the electricity supply has not been interrupted
and that the appliance is connected correctly.
• Ensure that the isolating valves are open.
• Check that all external controls are connected correctly.
14 Servicing
• See the "Safety instructions" chapter for a list of operations
to be performed prior to the maintenance of the application.
• Once the maintenance operations have been completed,
refer to the system’s installation manual to restart the
installation.
Annual Maintenance
• Check the proper functioning of safety devices.
• Check the pressure of the circuits.
• Check the airtightness of the connections.
• Ensure that the appliance’s components are neither worn nor
broken.
15 Replacement of Parts
In order to guarantee the safe and prolonged life of the product,
manufacturers genuine spare parts must be used.
i
Use only the manufacturer’s authorised, original,
new spare parts.
• Ensure that spare parts are correctly mounted in the right
position and direction. After fitting any spare part or servicing,
the appliance must be tested for its safe operation.
16 Technical Data
Description
Unit
Value
Maximum heating circuit pressure
bar
3
Pa
3 x 10
5
Maximum heat pump circuit pressure
bar
3
Pa
3 x 10
5
Pump supply voltage
V/Hz
230 / 50
Thermistor supply voltage
V
3.3
Dimensions
Height mm
476
Length mm
470
Depth mm
200
Lift weight
kg
12,5